AXIS#.EIP.TP.POSCOUNT1
Description
AXIS#.EIP.TP.POSCOUNT1 reads the associated axis’ first touch probe counter, which is incremented with each rising edge of the touch probe 1 input.
The counter is only valid if touch probe 1 is enabled (AXIS#.EIP.TP.CONTROL1, bit 0 = 1b). When configured to capture only the first event only bit 0 changes. When configured for continuous triggering, the value is an unsigned 16-bit value with overflow. When configured for continuous triggering, the value is an unsigned 16-bit value with overflow.
Context
For more information on the usage of touch probes, see AKD2G EtherNet/IP Touch Probes.
Versions
| Action | Version | Notes |
|---|---|---|
| Implemented | 02-11-03-000 |
General Information
|
Type |
Read Only |
|
Units |
N/A |
|
Range |
0 to 65536 |
|
Default Value |
N/A |
|
Data Type |
Integer |
|
Stored in Non-Volatile Memory |
No |
Variants Supported
EtherNet/IP drives: AKD2G-SPI
Industrial Ethernet Information
|
ID |
Instance |
Attribute |
Name |
Data Type |
Access |
User Mappable |
|---|---|---|---|---|---|---|
|
7567 |
1 |
7567 (0x1d8f) |
AXIS1.EIP.TP.POSCOUNT1 |
Unsigned16 |
Read Only |
Yes |
|
73103 |
2 |
7567 (0x1d8f) |
AXIS2.EIP.TP.POSCOUNT1 |
Unsigned16 |
Read Only |
Yes |